Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 17.675
Filtrar
1.
J Environ Manage ; 357: 120774, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38569265

RESUMO

The booming electric vehicle market has led to an increasing number of end-of-life power batteries. In order to reduce environmental pollution and promote the realization of circular economy, how to fully and effectively recycle the end-of-life power batteries has become an urgent challenge to be solved today. The recycling & remanufacturing center is an extremely important and key facility in the recycling process of used batteries, which ensures that the recycled batteries can be handled in a standardized manner under the conditions of professional facilities. In reality, different adjustment options for existing recycling & remanufacturing centers have a huge impact on the planning of new sites. This paper proposes a mixed-integer linear programming model for the siting problem of battery recycling & remanufacturing centers considering site location-adjustment. The model allows for demolition, renewal, and new construction options in planning for recycling & remanufacturing centers. By adjusting existing sites, this paper provides an efficient allocation of resources under the condition of meeting the demand for recycling of used batteries. Next, under the new model proposed in this paper, the uncertainty of the quantity and capacity of recycled used batteries is considered. By establishing different capacity conditions of batteries under multiple scenarios, a robust model was developed to determine the number and location of recycling & remanufacturing centers, which promotes sustainable development, reduces environmental pollution and effectively copes with the risk of the future quantity of used batteries exceeding expectations. In the final results of the case analysis, our proposed model considering the existing sites adjustment reduces the cost by 3.14% compared to the traditional model, and the average site utilization rate is 15.38% higher than the traditional model. The results show that the model has an effective effect in reducing costs, allocating resources, and improving efficiency, which could provide important support for decision-making in the recycling of used power batteries.


Assuntos
Fontes de Energia Elétrica , Reciclagem , Incerteza , Reciclagem/métodos , Poluição Ambiental , Eletricidade
2.
PLoS One ; 19(4): e0301516, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38568998

RESUMO

The integration of renewable energy systems into electricity grids is a solution for strengthening electricity distribution networks (SEDNs). Renewable energies such as solar photovoltaics are suitable for reinforcing a low-voltage line by offering an electrical energy storage system. However, the integration of photovoltaic systems can lead to problems of harmonic distortion due to the presence of direct current or non-linear feedback in networks from other sources. Therefore, connection standards exist to ensure the quality of the energy before injection at a point of common coupling (PCC). In this work, particle swarm optimization (PSO) is used to control a boost converter and to evaluate the power losses and the harmonic distortion rate. The test on the IEEE 14 bus standard makes it possible to determine the allocation or integration nodes for other sources such as biomass, wind or hydrogen generators, in order to limit the impact of harmonic disturbances (LIHs). The evaluation of the harmonic distortion rate, the power losses as well as the determination of the system size is done using an objective function defined based on the integration and optimization constraints of the system. The proposed model performs better since the grid current and voltage are stabilized in phase after the photovoltaic source is injected.


Assuntos
Fontes de Energia Elétrica , Modelos Teóricos , Algoritmos , Energia Renovável , Eletricidade
3.
Nat Commun ; 15(1): 2938, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580690

RESUMO

Epithelial tissues sheath organs and electro-mechanically regulate ion and water transport to regulate development, homeostasis, and hydrostatic organ pressure. Here, we demonstrate how external electrical stimulation allows us to control these processes in living tissues. Specifically, we electrically stimulate hollow, 3D kidneyoids and gut organoids and find that physiological-strength electrical stimulation of ∼ 5 - 10 V/cm powerfully inflates hollow tissues; a process we call electro-inflation. Electro-inflation is mediated by increased ion flux through ion channels/transporters and triggers subsequent osmotic water flow into the lumen, generating hydrostatic pressure that competes against cytoskeletal tension. Our computational studies suggest that electro-inflation is strongly driven by field-induced ion crowding on the outer surface of the tissue. Electrically stimulated tissues also break symmetry in 3D resulting from electrotaxis and affecting tissue shape. The ability of electrical cues to regulate tissue size and shape emphasizes the role and importance of the electrical micro-environment for living tissues.


Assuntos
Eletricidade , Água , Homeostase , Pressão Hidrostática , Osmose
4.
Sensors (Basel) ; 24(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610312

RESUMO

Electrocardiogram (ECG) reconstruction from contact photoplethysmogram (PPG) would be transformative for cardiac monitoring. We investigated the fundamental and practical feasibility of such reconstruction by first replicating pioneering work in the field, with the aim of assessing the methods and evaluation metrics used. We then expanded existing research by investigating different cycle segmentation methods and different evaluation scenarios to robustly verify both fundamental feasibility, as well as practical potential. We found that reconstruction using the discrete cosine transform (DCT) and a linear ridge regression model shows good results when PPG and ECG cycles are semantically aligned-the ECG R peak and PPG systolic peak are aligned-before training the model. Such reconstruction can be useful from a morphological perspective, but loses important physiological information (precise R peak location) due to cycle alignment. We also found better performance when personalization was used in training, while a general model in a leave-one-subject-out evaluation performed poorly, showing that a general mapping between PPG and ECG is difficult to derive. While such reconstruction is valuable, as the ECG contains more fine-grained information about the cardiac activity as well as offers a different modality (electrical signal) compared to the PPG (optical signal), our findings show that the usefulness of such reconstruction depends on the application, with a trade-off between morphological quality of QRS complexes and precise temporal placement of the R peak. Finally, we highlight future directions that may resolve existing problems and allow for reliable and robust cross-modal physiological monitoring using just PPG.


Assuntos
Eletrocardiografia , Fotopletismografia , Estudos de Viabilidade , Benchmarking , Eletricidade
5.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610371

RESUMO

Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.


Assuntos
Eletricidade , Animais , Bovinos , Reprodutibilidade dos Testes , Biópsia
6.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610372

RESUMO

The build-up of lactate in solid tumors stands as a crucial and early occurrence in malignancy development, and the concentration of lactate in the tumor microenvironment may be a more sensitive indicator for analyzing primary tumors. In this study, we designed a self-powered lactate sensor for the rapid analysis of tumor samples, utilizing the coupling between the piezoelectric effect and enzymatic reaction. This lactate sensor is fabricated using a ZnO nanowire array modified with lactate oxidase (LOx). The sensing process does not require an external power source or batteries. The device can directly output electric signals containing lactate concentration information when subjected to external forces. The lactate concentration detection upper limit of the sensor is at least 27 mM, with a limit of detection (LOD) of approximately 1.3 mM and a response time of around 10 s. This study innovatively applied self-powered technology to the in situ detection of the tumor microenvironment and used the results to estimate the growth period of the primary tumor. The availability of this application has been confirmed through biological experiments. Furthermore, the sensor data generated by the device offer valuable insights for evaluating the likelihood of remote tumor metastasis. This study may expand the research scope of self-powered technology in the field of medical diagnosis and offer a novel perspective on cancer diagnosis.


Assuntos
Nanofios , Neoplasias , Humanos , Ácido Láctico , Neoplasias/diagnóstico , Fontes de Energia Elétrica , Eletricidade , Microambiente Tumoral
7.
Sensors (Basel) ; 24(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610409

RESUMO

Electrical impedance spectroscopy (EIS) has been proposed as a promising noninvasive method to differentiate healthy thyroid from parathyroid tissues during thyroidectomy. However, previously reported similarities in the in vivo measured spectra of these tissues during a pilot study suggest that this separation may not be straightforward. We utilise computational modelling as a method to elucidate the distinguishing characteristics in the EIS signal and explore the features of the tissue that contribute to the observed electrical behaviour. Firstly, multiscale finite element models (or 'virtual tissue constructs') of thyroid and parathyroid tissues were developed and verified against in vivo tissue measurements. A global sensitivity analysis was performed to investigate the impact of physiological micro-, meso- and macroscale tissue morphological features of both tissue types on the computed macroscale EIS spectra and explore the separability of the two tissue types. Our results suggest that the presence of a surface fascia layer could obstruct tissue differentiation, but an analysis of the separability of simulated spectra without the surface fascia layer suggests that differentiation of the two tissue types should be possible if this layer is completely removed by the surgeon. Comprehensive in vivo measurements are required to fully determine the potential for EIS as a method in distinguishing between thyroid and parathyroid tissues.


Assuntos
Espectroscopia Dielétrica , Glândula Tireoide , Glândula Tireoide/cirurgia , Projetos Piloto , Simulação por Computador , Eletricidade
8.
Int J Mol Sci ; 25(7)2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38612886

RESUMO

Stimuli-responsive supramolecular polymers are ordered nanosized materials that are held together by non-covalent interactions (hydrogen-bonding, metal-ligand coordination, π-stacking and, host-guest interactions) and can reversibly undergo self-assembly. Their non-covalent nature endows supramolecular polymers with the ability to respond to external stimuli (temperature, light, ultrasound, electric/magnetic field) or environmental changes (temperature, pH, redox potential, enzyme activity), making them attractive candidates for a variety of biomedical applications. To date, supramolecular research has largely evolved in the development of smart water-soluble self-assemblies with the aim of mimicking the biological function of natural supramolecular systems. Indeed, there is a wide variety of synthetic biomaterials formulated with responsiveness to control and trigger, or not to trigger, aqueous self-assembly. The design of responsive supramolecular polymers ranges from the use of hydrophobic cores (i.e., benzene-1,3,5-tricarboxamide) to the introduction of macrocyclic hosts (i.e., cyclodextrins). In this review, we summarize the most relevant advances achieved in the design of stimuli-responsive supramolecular systems used to control transport and release of both diagnosis agents and therapeutic drugs in order to prevent, diagnose, and treat human diseases.


Assuntos
Ciclodextrinas , Polímeros Responsivos a Estímulos , Humanos , Benzeno , Materiais Biocompatíveis , Eletricidade , Água
9.
Skin Res Technol ; 30(4): e13678, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616507

RESUMO

BACKGROUND: We developed and tested the safety and efficacy of a cosmetic device to improve dark circles using electrical muscle stimulation of the orbicularis oculi muscle. METHODS: Overall, 18 participants (36 eyes) were studied. The following five items were evaluated before and after the intervention:(1) the Clinical Dark Circle Score using clinical findings and photographs, (2) transcutaneous oxygen partial pressure (TcPO2) on the lower eyelid, (3) thermography, (4) two-dimensional laser blood flowmetry, and (5) spectrophotometry. RESULTS: The mean score at baseline was 2.0 ± 0.90 (mean ± standard deviation), and that at the end of the study was 1.2 ± 1.0 (Wilcoxon signed-rank sum test, p < 0.0001), indicating a significant reduction. The spectrophotometer showed a significant decrease in a* and L* values before and after use (Wilcoxon signed-rank sum test, p < 0.0001). There was also a weak negative correlation between the change in score and the change in blood flow and TcPO2 measured using a laser perfusion device (Spearman's rank correlation coefficient, r = -0.32 and -0.39, respectively). Stratified analysis of the baseline score showed a strong negative correlation between the change in score and the change in spectrophotometric a* in the subjects/group with mild periocular dark circles (Spearman's rank correlation coefficient, r = -0.46). Contrastingly, no correlation was observed for any of the measurements in the subjects/group with severe periocular dark circles. After 1 month, no device-related ophthalmic adverse events were observed in any of the participants. CONCLUSION: Electrical muscle stimulation could improve periocular dark circles, especially in the subjects/group with mild periocular dark circles, and was safe.


Assuntos
Pálpebras , Músculos Faciais , Humanos , Face , Estimulação Elétrica , Eletricidade
10.
Environ Sci Technol ; 58(16): 6964-6977, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38602491

RESUMO

The rapid reduction in the cost of renewable energy has motivated the transition from carbon-intensive chemical manufacturing to renewable, electrified, and decarbonized technologies. Although electrified chemical manufacturing technologies differ greatly, the feasibility of each electrified approach is largely related to the energy efficiency and capital cost of the system. Here, we examine the feasibility of ammonia production systems driven by wind and photovoltaic energy. We identify the optimal regions where wind and photovoltaic electricity production may be able to meet the local demand for ammonia-based fertilizers and set technology targets for electrified ammonia production. To compete with the methane-fed Haber-Bosch process, electrified ammonia production must reach energy efficiencies of above 20% for high natural gas prices and 70% for low natural gas prices. To account for growing concerns regarding access to water, geospatial optimization considers water stress caused by new ammonia facilities, and recommendations ensure that the identified regions do not experience an increase in water stress. Reducing water stress by 99% increases costs by only 1.4%. Furthermore, a movement toward a more decentralized ammonia supply chain driven by wind and photovoltaic electricity can reduce the transportation distance for ammonia by up to 76% while increasing production costs by 18%.


Assuntos
Amônia , Energia Renovável , Fertilizantes , Eletricidade , Vento
11.
PLoS One ; 19(4): e0300925, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593131

RESUMO

In this work, the electro-coalescence process of three nanodroplets under a constant DC electric field is investigated via molecular dynamics simulations (MD), aiming to explore the electric manipulation of multiple droplets coalescence on the molecular level. The symmetrical and asymmetrical dynamic evolutions of electrocoalescence process can be observed. Our MD simulations show that there are two types of critical electric fields to induce the special dynamics. The chain configuration can be formed, when one of the critical electric field is exceeded, referred to as Ecc. On the other hand, there is another critical electric field to change the coalescence pattern from complete coalescence to partial coalescence, the so-called Ecn. Finally, we find that the use of the pulsed DC electric field can overcome the drawbacks of the constant DC electric field in the crude oil industry, and the mechanisms behind the suppressed effect of the water chain or non-coalescence are further revealed.


Assuntos
Evolução Biológica , Eletricidade , Simulação de Dinâmica Molecular , Indústria de Petróleo e Gás , Extremidade Superior
12.
PLoS One ; 19(4): e0297750, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625921

RESUMO

High-voltage dry-type bushings, serving as the crucial junctions in DC power transmission, represent equipment with the highest failure rate on the DC primary side, underscoring the critical importance of monitoring their condition. Presently, numerical simulation methods are commonly employed to assess the internal state of bushings. However, due to limitations in the efficiency of multi-physics field computations, the guidance provided by numerical simulation results in the field of power equipment condition assessment is relatively weak. This paper focuses on solving the electrical-thermal coupling in high-voltage dry-type bushings. Addressing the most widely used tetrahedral mesh in numerical computations, we propose an efficient solution method based on the concept of "smooth domains." This method involves partitioning the volume centroids of the elements into multiple smooth domains within the computational domain. Electric and thermal conduction matrix calculations occur within these smooth domains, rather than within the grid or element interiors. This approach eliminates the need for traditional element mapping and complex volume integration. To demonstrate the effectiveness of this method, we use high-voltage dry-type bushings as a case study, comparing the performance of our approach with traditional finite element algorithms. We verify the algorithm's computational efficiency and apply it to the analysis of typical temperature anomalies in bushings, further illustrating its suitability for electrical equipment condition assessment.


Assuntos
Algoritmos , Eletricidade , Simulação por Computador , Temperatura , Sistemas Computacionais , Análise de Elementos Finitos
13.
PLoS One ; 19(4): e0302037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625923

RESUMO

The tear strength of textiles is a crucial characteristic of product quality. However, during the laboratory testing of this indicator, factors such as equipment operation, human intervention, and test environment can significantly influence the results. Currently, there is a lack of traceable records for the influencing factors during the testing process, and effective classification of testing activities is not achieved. Therefore, this study proposes a state-awareness and classification approach for fabric tear performance testing based on multi-source data. A systematic design is employed for fabric tear performance testing activities, which can real-time monitor electrical parameters, operational environment, and operator behavior. The data are collected, preprocessed, and a Decision Tree Support Vector Machine (DTSVM) is utilized for classifying various working states, and introducing ten-fold cross-validation to enhance the performance of the classifier, forming a comprehensive awareness of the testing activities. Experimental results demonstrate that the system effectively perceives fabric tear performance testing processes, exhibiting high accuracy in the classification of different fabric testing states, surpassing 98.73%. The widespread application of this system contributes to continuous improvement in the workflow and traceability of fabric tear performance testing processes.


Assuntos
Máquina de Vetores de Suporte , Têxteis , Humanos , Eletricidade , Percepção
14.
Sensors (Basel) ; 24(7)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38610511

RESUMO

Flexible neural probes are attractive emerging technologies for brain recording because they can effectively record signals with minimal risk of brain damage. Reducing the electrode impedance of the probe before recording is a common practice of many researchers. However, studies investigating the impact of low impedance levels on high-quality recordings using flexible neural probes are lacking. In this study, we electrodeposited Pt onto a commercial flexible polyimide neural probe and investigated the relationship between the impedance level and the recording quality. The probe was inserted into the brains of anesthetized mice. The electrical signals of neurons in the brain, specifically the ventral posteromedial nucleus of the thalamus, were recorded at impedance levels of 50, 250, 500 and 1000 kΩ at 1 kHz. The study results demonstrated that as the impedance decreased, the quality of the signal recordings did not consistently improve. This suggests that extreme lowering of the impedance may not always be advantageous in the context of flexible neural probes.


Assuntos
Lesões Encefálicas , Animais , Camundongos , Impedância Elétrica , Neurônios , Encéfalo , Eletricidade
15.
PLoS One ; 19(4): e0290150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38558006

RESUMO

In order to improve the interior sound quality of Electric Vehicles (EV), solve the problem of low sense of power and comfort of the interior sound as well as the large electromagnetic excitation order noise of motor and the sharp interior sound, this article designs a dynamic active sound control system for EV under accelerated driving conditions. Firstly, by comparing and analyzing the sound spectrum characteristics of fuel vehicle (FV) and EV during acceleration, a short-time Fourier transform (STFT) is adopted to extract and synthesize the engine sound. Secondly, the influence of the engine order composition and the energy distribution in the frequency domain on the sound quality of the vehicle is analyzed, and an active control system for sound quality is proposed. And the software and hardware development of the active control sound system is completed. Finally, through real-vehicle testing and verification, the sense of comfort and power of the EV interior sound has been greatly improved during acceleration, and the total value of interior sound can meet the requirement. The sound pressure level and loudness of interior sound have been increased, and the sharpness of the sound inside the vehicle has been improved, with a maximum reduction of 1.0acum.


Assuntos
Automóveis , Som , Ruído , Eletricidade , Aceleração
16.
Nano Lett ; 24(15): 4485-4492, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38578031

RESUMO

Confining DNA in nanochannels is an important approach to studying its structure and transportation dynamics. Graphene nanochannels are particularly attractive for studying DNA confinement due to their atomic flatness, precise height control, and excellent mechanical strength. Here, using femtosecond laser etching and wetting transfer, we fabricate graphene nanochannels down to less than 4.3 nm in height, with the length-to-height ratios up to 103. These channels exhibit high stability, low noise, and self-cleaning ability during the long-term ionic current recording. We report a clear linear relationship between DNA length and the residence time in the channel and further utilize this relationship to differentiate DNA fragments based on their lengths, ranging widely from 200 bps to 48.5 kbps. The graphene nanochannel presented here provides a potential platform for label-free analyses and reveals fundamental insights into the conformational dynamics of DNA and proteins in confined space.


Assuntos
Grafite , Eletricidade , Condutividade Elétrica , Proteínas , DNA/química
17.
Methods Mol Biol ; 2794: 221-244, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630233

RESUMO

The patch-clamp technique is one of the most useful tools to analyze the function of electrically active cells such as neurons. This technique allows for the analysis of proteins (ion channels and receptors), cells (neurons), and synapses that are the building blocks of neuronal networks. Cortical development involves coordinated changes in functional measures at each of these levels of analysis that reflect both cellular and circuit maturation. This chapter explains the technical and theoretical basis of patch-clamp methodology and introduces several examples of how this technique can be applied in the context of cortical development.


Assuntos
Eletricidade , Neurônios , Técnicas de Patch-Clamp , Sinapses
18.
PLoS One ; 19(4): e0301924, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630765

RESUMO

To satisfy the requirements of modern communication systems and wearables using 2.4/5.8 GHz band this paper presents a simple, compact, and dual-band solution. The antenna is extracted from a circular monopole by inserting various patches and stubs. The genetic algorithm is utilized to optimize the parameters and achieve the best possible results regarding bandwidth and gain. Afterward, a 2-port multiple-input-multiple-output (MIMO) configuration is created by positioning an identical second single element perpendicularly to the first one. The electrical size of the suggested MIMO configuration is 0.26 λL × 0.53 λL, where λL represents the free space wavelength at lower resonance of 2.45 GHz. The common ground technique is adopted to further reduce and achieve the accepted level of mutual coupling of the MIMO configuration. The presented MIMO antenna offers a low mutual coupling of < -27 dB with 0.2 envelope correlation coefficient (ECC). The antenna has a gain of around 6.2 dBi and 6.5 dBi at resonating frequencies of 2.45 GHz and 5.4 GHz. Furthermore, the specific absorption rate (SAR) analysis of the MIMO antenna offers a range inside of the standard values, showing its potential for On/Off body communications. The comparison with already published works shows that the proposed antenna achieves better results in either compact size or wide operational bandwidth along with low mutual coupling.


Assuntos
Dispositivos Eletrônicos Vestíveis , Comunicação , Eletricidade , Vibração
19.
Sci Total Environ ; 927: 172402, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38608888

RESUMO

Microbial fuel cells (MFCs) have significant potential for environmental remediation and energy recycling directly from refractory aromatic hydrocarbons. To boost the capacities of toluene removal and the electricity production in MFCs, this study constructed a polyaniline@carbon nanotube (PANI@CNT) bioanode with a three-dimensional framework structure. Compared with the control bioanode based on graphite sheet, the PANI@CNT bioanode increased the output voltage and toluene degradation kinetics by 2.27-fold and 1.40-fold to 0.399 V and 0.60 h-1, respectively. Metagenomic analysis revealed that the PANI@CNT bioanode promoted the selective enrichment of Pseudomonas, with the dual functions of degrading toluene and generating exogenous electrons. Additionally, compelling genomic evidence elucidating the relationship between functional genes and microorganisms was found. It was interesting that the genes derived from Pseudomonas related to extracellular electron transfer, tricarboxylic acid cycle, and toluene degradation were upregulated due to the existence of PANI@CNT. This study provided biomolecular insights into key genes and related microorganisms that effectively facilitated the organic pollutant degradation and energy recovery in MFCs, offering a novel alternative for high-performance bioanode.


Assuntos
Fontes de Energia Bioelétrica , Metagenômica , Nanotubos de Carbono , Tolueno , Tolueno/metabolismo , Compostos de Anilina , Biodegradação Ambiental , Eletricidade , Pseudomonas/metabolismo , Pseudomonas/genética , Eletrodos
20.
J Chem Phys ; 160(14)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38587228

RESUMO

Here, we demonstrate double-layer 3D vertical resistive random-access memory with a hole-type structure embedding Pt/HfOx/AlN/TiN memory cells, conduct analog resistive switching, and examine the potential of memristors for use in neuromorphic systems. The electrical characteristics, including resistive switching, retention, and endurance, of each layer are also obtained. Additionally, we investigate various synaptic characteristics, such as spike-timing dependent plasticity, spike-amplitude dependent plasticity, spike-rate dependent plasticity, spike-duration dependent plasticity, and spike-number dependent plasticity. This synapse emulation holds great potential for neuromorphic computing applications. Furthermore, potentiation and depression are manifested through identical pulses based on DC resistive switching. The pattern recognition rates within the neural network are evaluated, and based on the conductance changing linearly with incremental pulses, we achieve a pattern recognition accuracy of over 95%. Finally, the device's stability and synapse characteristics exhibit excellent potential for use in neuromorphic systems.


Assuntos
Eletricidade , Redes Neurais de Computação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...